Difference between revisions of "20.109(F20):M1D5"

From Course Wiki
Jump to: navigation, search
(Part 3: Prepare CometChip)
 
(76 intermediate revisions by one user not shown)
Line 8: Line 8:
 
For the next experiment in this module you will use the CometChip assay developed in the Engelward Laboratory.  The CometChip assay is used to assess various types of DNA lesions, including base excisions, abasic sites, strand breaks, and crosslinks.
 
For the next experiment in this module you will use the CometChip assay developed in the Engelward Laboratory.  The CometChip assay is used to assess various types of DNA lesions, including base excisions, abasic sites, strand breaks, and crosslinks.
  
[[Image:Fa16 M1D1 introduction.png|thumb|right|350px|'''CometChip assay results.''']]To measure DNA damage, the CometChip assay relies on gel electrophoresis.  Electrophoresis is a technique used to separate molecules by size using an applied electrical field and a sieving matrix. DNA, RNA and proteins are often studied with this technique; agarose and acrylamide gels are the two most common sieves. The molecules to be separated enter the matrix through a well at one end and are pulled through the matrix when a current is applied. Because DNA and RNA are negatively charged molecules due to their phosphate backbone, they naturally travel toward the positive charge at the far end of the gel.  Larger molecules are entwined in the matrix and are stalled; smaller molecules wind through the matrix more easily and travel further from the well. Over time fragments of similar length accumulate into 'bands' in the gel.  The CometChip assay is based upon the principle that damaged DNA travels more readily compared to undamaged DNA.
+
[[Image:Fa16 M1D1 introduction.png|thumb|right|350px|'''Microscopy images showing results from CometChip assay.''' A. In the CometChip assay DNA damage is measured by determining the amount of DNA in the head versus the tail of the comet. B. Cells not treated with DNA damaging agent (left) have visibly less DNA damage that cells treated with DNA damaging agent (right) as evidenced by the amount of DNA in the tail.]]To measure DNA damage, the CometChip assay relies on gel electrophoresis.  Electrophoresis is a technique used to separate molecules by size using an applied electrical field and a sieving matrix. DNA, RNA and proteins are often studied with this technique; agarose and acrylamide gels are the two most common sieves. The molecules to be separated enter the matrix through a well at one end and are pulled through the matrix when a current is applied. Because DNA and RNA are negatively charged molecules due to their phosphate backbone, they naturally travel toward the positive charge at the far end of the gel.  Larger molecules are entwined in the matrix and are stalled; smaller molecules wind through the matrix more easily and travel further from the well. Over time fragments of similar length accumulate into 'bands' in the gel.  The CometChip assay is based upon the principle that damaged DNA travels more readily compared to undamaged DNA.
  
 
In the CometChip assay, cells are loaded into microwells that are 'stamped' onto an agarose gel sieving matrix.  Specific treatments can then be applied to the cells within these microwells that induce DNA damage.  The cells are then lysed to release the DNA into the microwell.  Following cell lysis, the CometChip is incubated in an alkaline buffer that unwinds the DNA.  This step allows for all types of DNA damage to be detected.  Lastly, gel electrophoresis is used to separate the DNA fragments.  DNA fragments migrate away from the microwell and generate a comet tail as shown in the image to the right (panel A).  The distance that the DNA migrates (''i.e.'' the length of the comet tail) is proportional to the amount of damage.  For example, with cells not treated with a DNA damaging agent, there are no evident comet tails to the right of the microwell or 'head' (panel B, image on the left); however, in cells treated with a DNA damaging agent there are comet tails apparent (panel B, image on the right). Comet tail lengths can be compared across experimental treatments to determine the deleterious effects of chemicals and toxins on DNA stability.  In addition, the CometChip assay can be used to study the rate and efficiency of repair in response to specific treatments.
 
In the CometChip assay, cells are loaded into microwells that are 'stamped' onto an agarose gel sieving matrix.  Specific treatments can then be applied to the cells within these microwells that induce DNA damage.  The cells are then lysed to release the DNA into the microwell.  Following cell lysis, the CometChip is incubated in an alkaline buffer that unwinds the DNA.  This step allows for all types of DNA damage to be detected.  Lastly, gel electrophoresis is used to separate the DNA fragments.  DNA fragments migrate away from the microwell and generate a comet tail as shown in the image to the right (panel A).  The distance that the DNA migrates (''i.e.'' the length of the comet tail) is proportional to the amount of damage.  For example, with cells not treated with a DNA damaging agent, there are no evident comet tails to the right of the microwell or 'head' (panel B, image on the left); however, in cells treated with a DNA damaging agent there are comet tails apparent (panel B, image on the right). Comet tail lengths can be compared across experimental treatments to determine the deleterious effects of chemicals and toxins on DNA stability.  In addition, the CometChip assay can be used to study the rate and efficiency of repair in response to specific treatments.
 
<br style="clear:both" />
 
<br style="clear:both" />
  
==Protcols==
+
==Protocols==
  
===Part 1: Load CometChip===
+
===Part 1: Participate in Comm Lab workshop===
You will use a CometChip and cells prepared for you by the Instructors to load the CometChip in the main laboratory.  It is important that you consider the following details before loading for your experiment.
+
#The density of your cell suspension (500K cells / mL) will determine the volume you load into each macrowell of the CometChip.
+
#*Calculate the volume of cell suspension that you will need to load such that 25K cells (or the number your group determined was optimal) are added to each macrowell.  Check your math with the Instructor before moving forward.
+
#Retrieve a CometChip from the front laboratory bench.[[Image:Fa19 20109 cometchip map.png|thumb|350px|right|CometChip diagram showing well alignment.]]
+
#*You will also need to gather one glass plate, one 96-well bottomless plate, and four 1.5" binder clips from the front bench.
+
#Remove your CometChip from the 1x PBS and place it, gelbond side down, on the glass plate.
+
#Press the 96-well bottomless plate upside-down onto the CometChip so that the wells line up with your labeling as shown in the diagram on the right!
+
#*The total size of the CometChip should be 5 wells across and six wells down.  You should have extra space / wells around the perimeter.
+
#*Be sure to press the top of the 96-well bottomless plate onto the CometChip.  If you are unsure which side is the top, please ask the teaching faculty.
+
#*Do not move the 96-well bottomless plate while it is on the CometChip as you will damage the agarose and the microwells.
+
#Use the binder clips to secure the 96-well bottomless plate to the glass plate, thus creating a 'sandwich' with your CometChip in the center.
+
#*Fasten the binder clips to the very edge of 96-well bottomless plate as shown in the image below. [[Image:Fa16 M1D2 binder clip image.png|thumb|200px|right|Binder clip placement for CometChip sandwich.]]
+
#*You will load into 30 wells total; 5 across by 6 down according to the map on the right!
+
#Add the appropriate volume of your cell suspension (calculated in Step #1) to each of the macrowells.
+
#Cover the top of your CometChip with plastic wrap then incubate in the 37 &deg;C incubator in the main laboratory for 15 min.
+
#After the incubation, complete a wash step to remove excess cells that are not within the microwells of your CometChip. Read all the bullets below before proceeding!
+
#*Carefully remove the binder clips and the 96-well bottomless plate.
+
#*With the CometChip on the glass plate, 'waterfall' ~5 mL of 1x PBS over the wells.
+
#**Hold the glass plate at a 45&deg; angle over the dish that you used to store your CometChip. 
+
#**Pipet up ~5 mL of 1x PBS.
+
#**Press the pipet tip onto the glass plate above your CometChip.
+
#**As you expel the 1x PBS, move the pipet tip from left-to-right.
+
#**The 1x PBS should pass over the top of the CometChip and fall into the dish.
+
#*Use a P200 tip attached to the pasteur pipet to aspirate the excess liquid from your CometChip wells.
+
#**Lightly touch the tip to the bottom of each imprinted well on the CometChip and ''immediately'' lift the tip from the agarose.
+
#Use the molten 1% low melting point (LMP) agarose is located in the 42 &deg;C waterbath on the front laboratory bench to 'trap' the cells in your CometChip.
+
#*You will need to work quickly from this point as the LMP agarose will solidify as it cools.
+
#Using the P1000, pipet up 1000 &mu;L of molten agarose from the bottle.
+
#Hold the pipet tip over the top left well of your CometChip and as you expel the agarose move the pipet tip from left to right.  Ensure that each row of your CometChip gets covered.
+
#*The goal is to lightly cover the wells that contain cells, which will 'trap' the cells into the microwells.
+
#*If the LMP agar 'fell' off the CometChip in any areas during this process, it is important to 'fill in' those portions of the CometChip.  Please alert the teaching faculty if you experience any difficulties!
+
#Leave your CometChip undisturbed on the benchtop for 3 min then carefully move it to the 4 &deg;C cooler for 5 min to ensure the LMP agarose solidifies.
+
#Use the microscope in the main laboratory to ensure you have cells loaded into your CometChip.
+
  
===Part 2: Treat cells for DNA damage experiment===
+
Our communication instructors, Dr. Prerna Bhargava and Dr. Sean Clarke, will join us today for a discussion on crafting Figures and Captions.
  
'''Apply MMS treatment'''
+
===Part 2: Learn about the CometChip===
  
#While the LMP agar is solidifying at 4 &deg;C, calculate the dilution of MMS that you will use for your experiment.
+
As discussed in the prelab lecture, you will use two methods to assess DNA damage: the &gamma;H2AX assay and the CometChip. Before we review the CometChip experimental details, it is best to familiarize yourself with the procedure and assay.
#*The MMS stock solution is at a 12 mM concentration.
+
#*You will add 100 &mu;L per well to induce DNA damage.
+
#*Calculate the dilution for a dose of 0.4 mM.
+
#Obtain an aliquot of MMS and prepare the dose that you calculated in Step #1 using DMEM media without supplements as the diluent.
+
#*Be very careful with MMS and work on the absorbent paper at all times![[File:Fa19 20109 cometchip treatment map.png|thumb|right|400px| '''DNA damage experiment plate map.''']]
+
#Retrieve your CometChip from the 4 &deg;C and carefully replace the bottomless 96-well plate to recreate the wells that you used for cell loading.
+
#*Secure the bottomless 96-well plate with binder clips as before.
+
#Add 100 &mu;L of either DMEM or DMEM + 0.4 mM MMS to the appropriate wells according to the plate map on the right.
+
#Carefully transport your CometChip to the 37 &deg;C incubator in TC for 1 hour.
+
  
'''Apply As treatment'''
+
Read the Abstract and Introduction in the following publication:
  
#During the MMS treatment, calculate the dilutions of As that you will use.
+
[[Media:CometChip Jove article.pdf| CometChip: A high-throughput 96-well platform for measuring DNA damage in microarrayed human cells.]] ''Journal of Visualized Experiments.'' (2014) 92: 1-11.
#*The As stock is at a 100 mM concentration.
+
#*You will add 100 &mu;L per well to induce DNA damage.
+
#*Calculate dilutions that result in doses of 0, 20, 40, 60, and 80 &mu;M.  
+
#Confirm your match with the teaching faculty, then prepare the dilutions with ~15 min remaining in the MMS treatment.
+
#*Obtain an aliquot of As and prepare the dose that you calculated in Step #1 using DMEM media without supplements as the diluent.
+
#*Prepare the doses that you calculated in a 12-well reservoir as discussed in prelab.
+
#*As before, be very careful with As and work on the absorbent paper at all times!
+
#Retrieve your CometChip from the 37 &deg;C incubator and use the P200 set at ~120 &mu;L to remove the DMEM or DMEM + 0.4 mM MMS.
+
#Using a multi-channel pipetman, add the appropriate treatment doses of As to each well of your CometChip.
+
#*The 0 &mu;M treatment should be added to the wells at the far left and the 80 &mu;M treatment should be added to the wells at the far right of the CometChip.
+
#Carefully transport your CometChip to the 37 &deg;C incubator in TC for 2 hours.
+
#Rinse your CometChip using 1x PBS into the same dish used during the cell loading procedure.
+
  
===Part 3: Complete staining for gamma-H2AX assay===
+
<font color = #4a9152 >'''In your laboratory notebook,'''</font color> answer the following questions:  
#Make sure to have TBS solution available before you start. Aspirate the secondary antibody solution off the coverslip and immediately add 150 &mu;L of TBS. Do not let the coverslips dry out during this process.
+
*Why is it important to study DNA damage?
#To complete the post secondary wash, add 150 &mu;L of TBS per coverslip, let incubate at room temperature for 3 min covered, then aspirate.
+
**You can consider the information provided in lecture / prelab to answer this question.
#To add DAPI, dilute the DAPI stain 1:1000 in TBS and add 150 &mu;L DAPI per coverslip. Let incubate at room temperature for 10 min covered, then aspirate.
+
*How does the CometChip estimate the level of DNA damage within cells?
#Add TBS as in step 2 for the final wash and leave for 3 min. Do no aspirate.
+
*List two issues / problems with the comet assay?
#Obtain glass slides from the front laboratory bench and label your slides with all of your experimental information and group name, add one drop of mounting media to the slide.
+
*List two improvements provided by the CometChip assay?
#Aspirate the final TBS wash and using tweezers place the coverslip cell-side down on the mounting media "spot" on the microscope slide. Try your best to avoid bubbles by slowly placing the coverslip over the mounting media.
+
#*The cell-side of the coverslip is the side that was facing up in the staining chamber.
+
#Complete Steps #5-6 for coverslips from all of the coverslips you stained.
+
# Add one small drop of nail polish to each side of your coverslip to seal it to the glass slide.
+
  
===Part 4: Complete cell lysis===
+
===Part 3: Prepare CometChip===
  
#Use the same dish your CometChip was stored in at the start of lab and a 30 mL aliquot of alkaline lysis buffer from the front laboratory bench.
+
[[Image:Fa18 M1D2 macrowell vs microwell.png|thumb|250px|right|'''Image of CometChip''' showing distinction between (A) 'macrowell' and (B) 'microwell'.]]The CometChip is simply a thin layer of agarose with microwells.  It is important to differentiate between the terms 'macrowell' and 'microwell' for your experiments. A bottomless 96-well plate is placed on top of the agarose CometChip to create the macrowells for the CometChip assay (panel A).  This enables researchers to control which cells are exposed to which treatment. The microwells were stamped into the agarose when you made your CometChip (panel B).  Within each well are ~ 300 microwells, which are ~40 &mu;m in diameter and 40 &mu;m in depth.
#Carefully move your CometChip into the dish.
+
#Add the aliquot of alkaline lysis solution by slowly pouring it into a corner of the dish rather than directly over the CometChip.
+
#*Be sure the CometChip is completely submerged and not floating in the dish.
+
#Label the dish with your team and section information.
+
#Move your dish into the 4 °C cooler.
+
  
The teaching faculty will transfer your CometChip from the alkaline lysis solution into 1X PBS at ~24 hr.
+
<font color = #0d368e>'''To ensure the steps required for preparing a CometChip are clear, the Instructor will provide a live demonstration of this process. You should provide a written description of the procedure in your laboratory notebook!'''</font color>
  
==Reagents list==
+
<font color = #4a9152 >'''In your laboratory notebook,'''</font color> complete the following:
*agar, low melting point (from Invitrogen)
+
*Provide a written overview / description of the the procedure used to prepare a CometChip (from the live demonstration).
*phosphate buffered saline (PBS) (from VWR)
+
*Onto which side of the GelBond is the agarose poured to make a CometChip?
*Dulbecco's Modified Eagle's Medium (DMEM) (from Gibco), without supplements
+
*How are the microwells generated in the agarose of the CometChip?
*methyl methanosulfonate (MMS) (from Sigma)
+
*arsenite (As) (from Sigma)
+
*alkaline lysis solution: 2.5 M NaCl, 100 mM Na<sub>2</sub>EDTA, 10 mM Tris, 1% Trition-X
+
  
==Navigation links==
 
Next day: [[20.109(F19):Complete CometChip experiment (Day5)| Quantify repair foci via network algorithm and complete high-throughput genome damage assay]]<br>
 
Previous day: [[20.109(F19):Complete gamma-H2AX assay and prepare CometChip (Day3)| Perform immunofluorescence assay for repair foci and optimize high-throughput genome damage assay]]<br>
 
  
 +
A video demonstrating the finishing procedure to make a CometChip is linked here: [https://www.dropbox.com/s/nufmtrashmu4160/%20Finishing%20the%20CometChip.mp4?dl=0 Making the CometChip]
  
===Part 2: Learn about the CometChip===
+
<br style="clear:both" />
  
As discussed in the prelab lecture, you will use two methods to assess DNA damage: the &gamma;H2AX assay and the CometChip.  In the next laboratory session you will construct a CometChip; however, it is best to familiarize yourself with the procedure and assay before then.
+
===Part 4: Perform CometChip experiment===
  
Read the Abstract and Introduction in the following publication:
+
As with the &gamma;H2AX experiment, the MCL-5 cells with be treated with H2O2 +/- As exposure. The treatments will be applied in two parts. First, cells will be incubated in As for 24 hrs to mimic exposure to the toxic metal. Second, the cells will be incubated in H2O2 for 20 min to induce DNA damage. Following treatment with H2O2 the cells will be visualized at the different timepoints to assess DNA repair.
  
[[Media:CometChip Jove article.pdf| CometChip: A high-throughput 96-well platform for measuring DNA damage in microarrayed human cells.]] ''Journal of Visualized Experiments.'' (2014) 92: 1-11.
+
<font color = #0d368e>'''To ensure the steps included below are clear, please watch the video tutorial (linked [http://www.jove.com/video/50607/cometchip-high-throughput-96-well-platform-for-measuring-dna-damage here]). The steps are detailed below so you can follow along!'''</font color>  Please note that the video shows the general steps for completing an experiment using the CometChip assay.  The specific procedure used to generate the data you will analyze are written below.  Furthermore, the video shows two version of the CometChip assay: the alkaline and the neutral.  In this module, the alkaline CometChip assay was used.
  
Answer the following questions (be sure to transfer the information to your laboratory notebook!):
+
'''Expose cells to As'''
#Why is it important to study DNA damage?
+
#*You can consider the information provided in lecture / prelab to answer this question.
+
#How does the CometChip estimate the level of DNA damage within cells?
+
#List two issues / problems with the comet assay?
+
#List two improvements provided by the CometChip assay?
+
  
Next, watch the following video to help you prepare for the next laboratory session: [http://www.jove.com/video/50607/cometchip-high-throughput-96-well-platform-for-measuring-dna-damage linked here].
+
#For each As treatment concentration, harvest and pellet 2 M cells by centrifuging at 200 g for 5 min at room temperature.
 +
#Prepare 2 &mu;M and 10 &mu;M As treatment concentrations in media.
 +
#Resuspend each cell pellet in 6 mL of the As-containing media.
 +
#Transfer cell suspensions to fresh T25 flasks and incubate at 37 &deg;C for 24 hrs.
  
===Part 2: Prepare CometChip===
+
'''Load cells into CometChip'''
  
#Obtain a sheet of gelbond film from the laboratory bench at the front of the room.  The paper is protecting the hydrophilic side of the gelbond film.
 
#*Be sure to keep the paper associated with the gelbond film so you know which side is which.
 
#Also obtain a special permanent marker from the front bench (Secureline Marker II).
 
#*If you use a marker from your drawer the ink will wash off during a later step in the CometChip assay protocol.
 
#Use the ruler in your team drawer and the Secureline permanent marker to draw a 4.5 x 3.5 cm rectangle near the center on the hydrophobic side of the gelbond film. Label three rows--'A', 'B', and 'C'--along the outside of the long side of the rectangle. [[Image:Fa19 20109 cometchip for cell loading.png| thumb| 350px|right| GelBond marking for CometChip]]
 
#*Note: you are writing on what will be the bottom of the CometChip and may want to write backwards so the labels are clear when you look at the top of your CometChip.
 
#Prepare 20 mL of 1% normal melting point (NMP) agarose.  '''Be careful as the agarose solution will be very hot!'''
 
#*Calculate the amount of NMP agarose powder needed for a 1% w/v solution.  Check your math with the teaching faculty before you continue.
 
#*Obtain a small milk bottle from the front bench.
 
#*Weigh out the appropriate amount of NMP agarose and add it to the milk bottle.
 
#*Use a cylinder to measure 20 mL of 1x PBS and add it to the milk bottle with the NMP agarose powder.
 
#*Swirl to mix.
 
#*To melt the NMP agarose, microwave the solution for 20 seconds, swirl, then microwave for 3-second intervals until all crystals are in solutions.  After each interval, remove the milk bottle and gently swirl while checking for unmelted agarose crystals.  '''It is important that the solution does NOT boil as you will lose water to evaporation and the density of the agarose will be altered.  If your solution starts to boil, immediately remove it from the microwave and gently swirl.'''
 
#*When no more crystals are visible in the solution take the milk bottle to your bench.
 
#Obtain a small rectangle dish (labeled "scraped lid") and the CometChip 'stamp' from the front bench.
 
#Add 2.5 mL of the agarose solution to the small dish, then ''quickly'' place the gelbond film in the dish with the marked hydrophobic side down. Remove the paper from the film.
 
#Add 13 mL of the agarose solution on top of the gelbond film.
 
#Slowly place the CometChip stamp on top of the agarose.
 
#*Lower the bottom left of the stamp first, then slowly allow the stamp to 'roll' into the agarose. Be sure to leave the top right corner of the small dish accessible.
 
#*Be careful not to introduce bubbles into the agarose and work quickly as the agarose will solidify as it cools.
 
#Allow the agarose to solidify, undisturbed, on your bench for 30 min.
 
#Add ~5 mL of 1x PBS to the small dish that contains your agarose CometChip.
 
#*Pipet in the 1x PBS using the accessible corner.
 
#Slowly pull from one corner of the stamp to lift it away from your CometChip in the dish.
 
#*If the CometChip sticks to the stamp, carefully peel it off using tweezers.
 
#*Discard the PBS in the sink.
 
#Remove excess agarose from the perimeter of your CometChip using a razor blade (obtain and return razor blade to front bench).
 
#Clean the agarose from the bottom of your CometChip (gelbond side) using a Kimwipe.
 
#Place your CometChip in the small dish containing 1x PBS for storage at 4 &deg;C until next time.
 
#*Be sure the chip is completely submerged.
 
#Please return the stamp to the front bench. Never wipe the stamp as that will ruin the microposts!
 
 
===Part 3: Load CometChip===
 
 
#Retrieve your CometChip from the 4 &deg;C cooler.[[Image:Fa19 20109 cometchip cell loading map.png|thumb|350px|right|CometChip diagram showing well alignment.]]
 
#*You will also need to gather one glass plate, one 96-well bottomless plate, and four 1.5" binder clips from the front bench.
 
 
#Remove your CometChip from the 1x PBS and place it, gelbond side down, on the glass plate.
 
#Remove your CometChip from the 1x PBS and place it, gelbond side down, on the glass plate.
#Press the 96-well bottomless plate upside-down onto the CometChip so that the wells line up with your labeling as shown in the diagram on the right.
+
#Press the 96-well bottomless plate upside-down onto the CometChip.
#*Be sure to press the top of the 96-well bottomless plate onto the CometChip.  If you are unsure which side is the top, please ask the teaching faculty.
+
#*Be sure to press the top of the 96-well bottomless plate onto the CometChip.   
 
#*Do not move the 96-well bottomless plate while it is on the CometChip as you will damage the agarose and the microwells.
 
#*Do not move the 96-well bottomless plate while it is on the CometChip as you will damage the agarose and the microwells.
 
#Use the binder clips to secure the 96-well bottomless plate to the glass plate, thus creating a 'sandwich' with your CometChip in the center.
 
#Use the binder clips to secure the 96-well bottomless plate to the glass plate, thus creating a 'sandwich' with your CometChip in the center.
 
#*Fasten the binder clips to the very edge of 96-well bottomless plate as shown in the image below. [[Image:Fa16 M1D2 binder clip image.png|thumb|200px|right|Binder clip placement for CometChip sandwich.]]
 
#*Fasten the binder clips to the very edge of 96-well bottomless plate as shown in the image below. [[Image:Fa16 M1D2 binder clip image.png|thumb|200px|right|Binder clip placement for CometChip sandwich.]]
#*You will load into the white wells and the grey wells should remain empty.
+
#Add 25,000 cells into each of the macrowells.
#Add 50 &mu;L of 1x PBS to the Condition A wells.
+
#Add the appropriate volume of your cell suspension (calculated in Part #2) to the Condition B and C wells.
+
 
#Cover the top of your CometChip with plastic wrap then incubate in the 37 &deg;C incubator in the main laboratory for 15 min.
 
#Cover the top of your CometChip with plastic wrap then incubate in the 37 &deg;C incubator in the main laboratory for 15 min.
 
#After the incubation, complete a wash step to remove excess cells that are not within the microwells of your CometChip. Read all the bullets below before proceeding!
 
#After the incubation, complete a wash step to remove excess cells that are not within the microwells of your CometChip. Read all the bullets below before proceeding!
 
#*Carefully remove the binder clips and the 96-well bottomless plate.
 
#*Carefully remove the binder clips and the 96-well bottomless plate.
#*'''Alert the teaching faculty at this point!  The wash step can be very temperamental and it is best to see a demonstration!'''
+
#*With the CometChip on the glass plate, 'waterfall' ~5 mL of 1x PBS over the wells.
#*With the CometChip on the glass plate, 'waterfall' ~5 mL of 1x PBS over the wells, which are now imprinted onto the agarose.
+
#**Hold the glass plate at a 45&deg; angle over the dish that you used to store your CometChip.   
#**Hold the glass plate with the CometChip such that Condition C is at the bottom.
+
#**To waterfall the 1x PBS, hold the glass plate at a 45&deg; angle over the dish that you used to store your CometChip.   
+
 
#**Pipet up ~5 mL of 1x PBS.
 
#**Pipet up ~5 mL of 1x PBS.
 
#**Press the pipet tip onto the glass plate above your CometChip.
 
#**Press the pipet tip onto the glass plate above your CometChip.
Line 193: Line 83:
 
#*Use a P200 tip attached to the pasteur pipet to aspirate the excess liquid from your CometChip wells.
 
#*Use a P200 tip attached to the pasteur pipet to aspirate the excess liquid from your CometChip wells.
 
#**Lightly touch the tip to the bottom of each imprinted well on the CometChip and ''immediately'' lift the tip from the agarose.
 
#**Lightly touch the tip to the bottom of each imprinted well on the CometChip and ''immediately'' lift the tip from the agarose.
#'''Read through Steps #11-14 before continuing with the procedure.'''
+
#Use the molten 1% low melting point (LMP) agarose is located in the 42 &deg;C waterbath on the front laboratory bench to 'trap' the cells in your CometChip.
#Retrieve one tube of molten 1% low melting point (LMP) agarose from the 42 &deg;C waterbath.
+
 
#*You will need to work quickly from this point as the LMP agarose will solidify as it cools.
 
#*You will need to work quickly from this point as the LMP agarose will solidify as it cools.
#Using the P1000, pipet up 1000 &mu;L of molten agarose from the tube.
+
#Using the P1000, pipet up 1000 &mu;L of molten agarose from the bottle.
 
#Hold the pipet tip over the top left well of your CometChip and as you expel the agarose move the pipet tip from left to right.  Ensure that each row of your CometChip gets covered.
 
#Hold the pipet tip over the top left well of your CometChip and as you expel the agarose move the pipet tip from left to right.  Ensure that each row of your CometChip gets covered.
 
#*The goal is to lightly cover the wells that contain cells, which will 'trap' the cells into the microwells.
 
#*The goal is to lightly cover the wells that contain cells, which will 'trap' the cells into the microwells.
#*If the LMP agar 'fell' off the CometChip in any areas during this process, it is important to 'fill in' those portions of the CometChip.  Please alert the teaching faculty if you experience any difficulties!
+
#*If the LMP agar 'fell' off the CometChip in any areas during this process, it is important to 'fill in' those portions of the CometChip.   
 
#Leave your CometChip undisturbed on the benchtop for 3 min then carefully move it to the 4 &deg;C cooler for 5 min to ensure the LMP agarose solidifies.
 
#Leave your CometChip undisturbed on the benchtop for 3 min then carefully move it to the 4 &deg;C cooler for 5 min to ensure the LMP agarose solidifies.
#Use the microscope in the main laboratory to image your CometChip.  You will use these images to determine: 1. the number of microwells that are loaded / total number of microwells in the frame and 2. the number of cells / microwell.
+
#Use a microscope to ensure you have cells loaded into your CometChip (see image below).
  
 +
[[Image:Fa20 M1D5 CometChip loading image v2.png|center|700px|thumb|'''Microscopy image of loaded CometChip.''' (A) Bottom of macrowell showing evenly spaced microwells. (B) Close-up of empty microwell.  (C) Close-up of microwell loaded with cells.]]
  
 +
<font color =  #4a9152 >'''In your laboratory notebook,'''</font color> complete the following:
 +
*Calculate the volume of cell suspension added to each macrowell for the CometChip assay.
 +
**The cell suspension is 500K cells / mL and 25,000 cells were added into each well.
 +
*Given the number of cells that were loaded into each macrowell, estimate the number of cells per microwell.
 +
**Consider the likelihood that every cell you add to the well will fall into a microwell. 
 +
**Perhaps calculate the surface area of the bottom of a well (of diameter 6.35 mm) and compare this to the size of the cells (~10 &mu;m).
 +
**Also, remember that within each macrowell there are ~ 300 microwells, which are ~40 μm in diameter and 40 μm in depth.
  
'''CometChip'''
+
'''Treat cells with H<sub>2</sub>O<sub>2</sub>'''
 +
 
 +
#While the LMP agar is solidifying at 4 &deg;C, prepare the 20 &mu;M treatment concentration of H<sub>2</sub>O<sub>2</sub> in DPBS.
 +
#*Be sure to prepare with DPBS as the diluent because the serum in media will inactivate H<sub>2</sub>O<sub>2</sub>.
 +
#*For the H<sub>2</sub>O<sub>2</sub> treatment conditions, As should also be included at the concentrations previously used for the exposure step.
 +
#Retrieve your CometChip from the 4 &deg;C and carefully attach a fresh bottomless 96-well plate to recreate the wells that you used for cell loading.
 +
#*Secure the bottomless 96-well plate with binder clips as before.
 +
#Add 50 &mu;L of either DPBS or DPBS + 20 &mu;M H<sub>2</sub>O<sub>2</sub> to the appropriate wells.
 +
#Carefully transport your CometChip to the 4 &deg;C cooler and incubate for 20 min.
 +
#Retrieve the CometChip from the cooler.
 +
#Remove the bottomless 96-well plate and quickly rinse the CometChip.
 +
#Immediately transfer the no H<sub>2</sub>O<sub>2</sub>-treatment macrowells and the 0 min macrowells to alkaline lysis buffer to stop the cellular response.
 +
#For the remaining macrowells, thoroughly rinse by washing DPBS over the CometChip a total of 3 times.
 +
#Secure a bottomless 96-well plate onto the CometChip and add fresh media to the remaining macrowells (15 min, 30 min, and 60 min).
 +
#*Again, As should also be included at the concentrations previously used for the exposure step.
 +
#Carefully transfer the CometChip to the 37 &deg;C incubator.
 +
#At the designated timepoints, retrieve your CometChip and transfer the appropriate macrowells to alkaline lysis buffer.
 +
#To ensure cell lysis is complete, incubate the CometChip macrowells in the 4 °C cooler for 24 hrs.
 +
 
 +
'''Electrophorese CometChip macrowells'''
 +
 
 +
#Remove your CometChip from the alkaline lysis buffer and wash in 1X PBS.
 +
#Use a kimwipe to dry the GelBond side.
 +
#Carefully move your CometChip to the gel electrophoresis station in the 4 &deg;C cold room.
 +
#Place your CometChip on the raised center region of an electrophoresis box.
 +
#*Double-sided tape was applied to the gel electrophoresis box.  Be sure you lay your CometChip on the tape strips and lightly press down with a pipet tip to ensure it is secure.
 +
#Add enough of the alkaline electrophoresis buffer to the gel electrophoresis box to cover your CometChip.
 +
#Leave the CometChip in the alkaline electrophoresis buffer (aka unwinding buffer) for 45 minutes.
 +
#To separate the damaged DNA into 'comets', electrophorese for 40 min (at 16 V, or 1 V/cm).
 +
#*It is important that the electrophoresis occur at 300 mA.  To maintain the appropriate current, the volume of electrophoresis buffer may need to be adjusted.  The teaching faculty will assist you in adding/removing electrophoresis buffer such that this value is reached.
 +
#Carefully remove your CometChip from the electrophoresis box and place it in a dish.
 +
#Obtain an aliquot of neutralization buffer from the front laboratory bench.
 +
#Wash your CometChip by adding enough neutralization buffer to cover (~10-12 mL) and incubate for 5 min at room temperature.
 +
#*Repeat this step for a total of 3 washes.
 +
#Add the SYBR gold DNA stain to your CometChip and carefully move it to the 4 &deg;C cooler.
 +
#*Stain CometChip overnight.
 +
 
 +
===Part 5: Edit homework assignment===
 +
 
 +
Using the pointers from the Comm Lab workshop, edit the figure (not the bullet text!) you prepared for the homework assignment due today.  You can submit the updated figure by 10 pm tonight for grading.  You will get a grade for submitting the original figure on-time and the updated figure will be graded for content.  If you choose not to update your homework, the figure already submitted will be graded for content.
 +
 
 +
==Reagents list==
 +
*agar, normal melting point (from Invitrogen)
 +
*GelBond film (from Lonza)
 
*agar, low melting point (from Invitrogen)
 
*agar, low melting point (from Invitrogen)
 
*phosphate buffered saline (PBS) (from VWR)
 
*phosphate buffered saline (PBS) (from VWR)
 +
*Dulbecco's phosphate buffered saline (DPBS) (from Sigma)
 +
*alkaline lysis solution: 2.5 M NaCl, 100 mM Na<sub>2</sub>EDTA, 10 mM Tris, 1% Trition-X
 +
*alkaline electrophoresis solution: 0.3 M NaOH, 1 mM Na<sub>2</sub>EDTA, pH 13.5 (from Sigma)
 +
*neutralization buffer: 0.4 M Tris, pH 7.5 (from Sigma)
 +
*SYBR gold DNA stain (from ThermoFisher)
 +
 +
==Navigation links==
 +
Next day: [[20.109(F20):M1D6 | Image and analyze high-throughput genome damage assay]]<br>
 +
Previous day: [[20.109(F20):M1D4 | Image repair foci experiment and quantify results]]<br>

Latest revision as of 22:13, 17 September 2020

20.109(F20): Laboratory Fundamentals of Biological Engineering

Fa20 banner image v2.png

Fall 2020 schedule        FYI        Assignments        Homework        Communication |        Accessibility

       M1: Genomic instability        M2: Drug discovery        M3: Metabolic engineering       


Introduction

For the next experiment in this module you will use the CometChip assay developed in the Engelward Laboratory. The CometChip assay is used to assess various types of DNA lesions, including base excisions, abasic sites, strand breaks, and crosslinks.

Microscopy images showing results from CometChip assay. A. In the CometChip assay DNA damage is measured by determining the amount of DNA in the head versus the tail of the comet. B. Cells not treated with DNA damaging agent (left) have visibly less DNA damage that cells treated with DNA damaging agent (right) as evidenced by the amount of DNA in the tail.
To measure DNA damage, the CometChip assay relies on gel electrophoresis. Electrophoresis is a technique used to separate molecules by size using an applied electrical field and a sieving matrix. DNA, RNA and proteins are often studied with this technique; agarose and acrylamide gels are the two most common sieves. The molecules to be separated enter the matrix through a well at one end and are pulled through the matrix when a current is applied. Because DNA and RNA are negatively charged molecules due to their phosphate backbone, they naturally travel toward the positive charge at the far end of the gel. Larger molecules are entwined in the matrix and are stalled; smaller molecules wind through the matrix more easily and travel further from the well. Over time fragments of similar length accumulate into 'bands' in the gel. The CometChip assay is based upon the principle that damaged DNA travels more readily compared to undamaged DNA.

In the CometChip assay, cells are loaded into microwells that are 'stamped' onto an agarose gel sieving matrix. Specific treatments can then be applied to the cells within these microwells that induce DNA damage. The cells are then lysed to release the DNA into the microwell. Following cell lysis, the CometChip is incubated in an alkaline buffer that unwinds the DNA. This step allows for all types of DNA damage to be detected. Lastly, gel electrophoresis is used to separate the DNA fragments. DNA fragments migrate away from the microwell and generate a comet tail as shown in the image to the right (panel A). The distance that the DNA migrates (i.e. the length of the comet tail) is proportional to the amount of damage. For example, with cells not treated with a DNA damaging agent, there are no evident comet tails to the right of the microwell or 'head' (panel B, image on the left); however, in cells treated with a DNA damaging agent there are comet tails apparent (panel B, image on the right). Comet tail lengths can be compared across experimental treatments to determine the deleterious effects of chemicals and toxins on DNA stability. In addition, the CometChip assay can be used to study the rate and efficiency of repair in response to specific treatments.

Protocols

Part 1: Participate in Comm Lab workshop

Our communication instructors, Dr. Prerna Bhargava and Dr. Sean Clarke, will join us today for a discussion on crafting Figures and Captions.

Part 2: Learn about the CometChip

As discussed in the prelab lecture, you will use two methods to assess DNA damage: the γH2AX assay and the CometChip. Before we review the CometChip experimental details, it is best to familiarize yourself with the procedure and assay.

Read the Abstract and Introduction in the following publication:

CometChip: A high-throughput 96-well platform for measuring DNA damage in microarrayed human cells. Journal of Visualized Experiments. (2014) 92: 1-11.

In your laboratory notebook, answer the following questions:

  • Why is it important to study DNA damage?
    • You can consider the information provided in lecture / prelab to answer this question.
  • How does the CometChip estimate the level of DNA damage within cells?
  • List two issues / problems with the comet assay?
  • List two improvements provided by the CometChip assay?

Part 3: Prepare CometChip

Image of CometChip showing distinction between (A) 'macrowell' and (B) 'microwell'.
The CometChip is simply a thin layer of agarose with microwells. It is important to differentiate between the terms 'macrowell' and 'microwell' for your experiments. A bottomless 96-well plate is placed on top of the agarose CometChip to create the macrowells for the CometChip assay (panel A). This enables researchers to control which cells are exposed to which treatment. The microwells were stamped into the agarose when you made your CometChip (panel B). Within each well are ~ 300 microwells, which are ~40 μm in diameter and 40 μm in depth.

To ensure the steps required for preparing a CometChip are clear, the Instructor will provide a live demonstration of this process. You should provide a written description of the procedure in your laboratory notebook!

In your laboratory notebook, complete the following:

  • Provide a written overview / description of the the procedure used to prepare a CometChip (from the live demonstration).
  • Onto which side of the GelBond is the agarose poured to make a CometChip?
  • How are the microwells generated in the agarose of the CometChip?


A video demonstrating the finishing procedure to make a CometChip is linked here: Making the CometChip


Part 4: Perform CometChip experiment

As with the γH2AX experiment, the MCL-5 cells with be treated with H2O2 +/- As exposure. The treatments will be applied in two parts. First, cells will be incubated in As for 24 hrs to mimic exposure to the toxic metal. Second, the cells will be incubated in H2O2 for 20 min to induce DNA damage. Following treatment with H2O2 the cells will be visualized at the different timepoints to assess DNA repair.

To ensure the steps included below are clear, please watch the video tutorial (linked here). The steps are detailed below so you can follow along! Please note that the video shows the general steps for completing an experiment using the CometChip assay. The specific procedure used to generate the data you will analyze are written below. Furthermore, the video shows two version of the CometChip assay: the alkaline and the neutral. In this module, the alkaline CometChip assay was used.

Expose cells to As

  1. For each As treatment concentration, harvest and pellet 2 M cells by centrifuging at 200 g for 5 min at room temperature.
  2. Prepare 2 μM and 10 μM As treatment concentrations in media.
  3. Resuspend each cell pellet in 6 mL of the As-containing media.
  4. Transfer cell suspensions to fresh T25 flasks and incubate at 37 °C for 24 hrs.

Load cells into CometChip

  1. Remove your CometChip from the 1x PBS and place it, gelbond side down, on the glass plate.
  2. Press the 96-well bottomless plate upside-down onto the CometChip.
    • Be sure to press the top of the 96-well bottomless plate onto the CometChip.
    • Do not move the 96-well bottomless plate while it is on the CometChip as you will damage the agarose and the microwells.
  3. Use the binder clips to secure the 96-well bottomless plate to the glass plate, thus creating a 'sandwich' with your CometChip in the center.
    • Fasten the binder clips to the very edge of 96-well bottomless plate as shown in the image below.
      Binder clip placement for CometChip sandwich.
  4. Add 25,000 cells into each of the macrowells.
  5. Cover the top of your CometChip with plastic wrap then incubate in the 37 °C incubator in the main laboratory for 15 min.
  6. After the incubation, complete a wash step to remove excess cells that are not within the microwells of your CometChip. Read all the bullets below before proceeding!
    • Carefully remove the binder clips and the 96-well bottomless plate.
    • With the CometChip on the glass plate, 'waterfall' ~5 mL of 1x PBS over the wells.
      • Hold the glass plate at a 45° angle over the dish that you used to store your CometChip.
      • Pipet up ~5 mL of 1x PBS.
      • Press the pipet tip onto the glass plate above your CometChip.
      • As you expel the 1x PBS, move the pipet tip from left-to-right.
      • The 1x PBS should pass over the top of the CometChip and fall into the dish.
    • Use a P200 tip attached to the pasteur pipet to aspirate the excess liquid from your CometChip wells.
      • Lightly touch the tip to the bottom of each imprinted well on the CometChip and immediately lift the tip from the agarose.
  7. Use the molten 1% low melting point (LMP) agarose is located in the 42 °C waterbath on the front laboratory bench to 'trap' the cells in your CometChip.
    • You will need to work quickly from this point as the LMP agarose will solidify as it cools.
  8. Using the P1000, pipet up 1000 μL of molten agarose from the bottle.
  9. Hold the pipet tip over the top left well of your CometChip and as you expel the agarose move the pipet tip from left to right. Ensure that each row of your CometChip gets covered.
    • The goal is to lightly cover the wells that contain cells, which will 'trap' the cells into the microwells.
    • If the LMP agar 'fell' off the CometChip in any areas during this process, it is important to 'fill in' those portions of the CometChip.
  10. Leave your CometChip undisturbed on the benchtop for 3 min then carefully move it to the 4 °C cooler for 5 min to ensure the LMP agarose solidifies.
  11. Use a microscope to ensure you have cells loaded into your CometChip (see image below).
Microscopy image of loaded CometChip. (A) Bottom of macrowell showing evenly spaced microwells. (B) Close-up of empty microwell. (C) Close-up of microwell loaded with cells.

In your laboratory notebook, complete the following:

  • Calculate the volume of cell suspension added to each macrowell for the CometChip assay.
    • The cell suspension is 500K cells / mL and 25,000 cells were added into each well.
  • Given the number of cells that were loaded into each macrowell, estimate the number of cells per microwell.
    • Consider the likelihood that every cell you add to the well will fall into a microwell.
    • Perhaps calculate the surface area of the bottom of a well (of diameter 6.35 mm) and compare this to the size of the cells (~10 μm).
    • Also, remember that within each macrowell there are ~ 300 microwells, which are ~40 μm in diameter and 40 μm in depth.

Treat cells with H2O2

  1. While the LMP agar is solidifying at 4 °C, prepare the 20 μM treatment concentration of H2O2 in DPBS.
    • Be sure to prepare with DPBS as the diluent because the serum in media will inactivate H2O2.
    • For the H2O2 treatment conditions, As should also be included at the concentrations previously used for the exposure step.
  2. Retrieve your CometChip from the 4 °C and carefully attach a fresh bottomless 96-well plate to recreate the wells that you used for cell loading.
    • Secure the bottomless 96-well plate with binder clips as before.
  3. Add 50 μL of either DPBS or DPBS + 20 μM H2O2 to the appropriate wells.
  4. Carefully transport your CometChip to the 4 °C cooler and incubate for 20 min.
  5. Retrieve the CometChip from the cooler.
  6. Remove the bottomless 96-well plate and quickly rinse the CometChip.
  7. Immediately transfer the no H2O2-treatment macrowells and the 0 min macrowells to alkaline lysis buffer to stop the cellular response.
  8. For the remaining macrowells, thoroughly rinse by washing DPBS over the CometChip a total of 3 times.
  9. Secure a bottomless 96-well plate onto the CometChip and add fresh media to the remaining macrowells (15 min, 30 min, and 60 min).
    • Again, As should also be included at the concentrations previously used for the exposure step.
  10. Carefully transfer the CometChip to the 37 °C incubator.
  11. At the designated timepoints, retrieve your CometChip and transfer the appropriate macrowells to alkaline lysis buffer.
  12. To ensure cell lysis is complete, incubate the CometChip macrowells in the 4 °C cooler for 24 hrs.

Electrophorese CometChip macrowells

  1. Remove your CometChip from the alkaline lysis buffer and wash in 1X PBS.
  2. Use a kimwipe to dry the GelBond side.
  3. Carefully move your CometChip to the gel electrophoresis station in the 4 °C cold room.
  4. Place your CometChip on the raised center region of an electrophoresis box.
    • Double-sided tape was applied to the gel electrophoresis box. Be sure you lay your CometChip on the tape strips and lightly press down with a pipet tip to ensure it is secure.
  5. Add enough of the alkaline electrophoresis buffer to the gel electrophoresis box to cover your CometChip.
  6. Leave the CometChip in the alkaline electrophoresis buffer (aka unwinding buffer) for 45 minutes.
  7. To separate the damaged DNA into 'comets', electrophorese for 40 min (at 16 V, or 1 V/cm).
    • It is important that the electrophoresis occur at 300 mA. To maintain the appropriate current, the volume of electrophoresis buffer may need to be adjusted. The teaching faculty will assist you in adding/removing electrophoresis buffer such that this value is reached.
  8. Carefully remove your CometChip from the electrophoresis box and place it in a dish.
  9. Obtain an aliquot of neutralization buffer from the front laboratory bench.
  10. Wash your CometChip by adding enough neutralization buffer to cover (~10-12 mL) and incubate for 5 min at room temperature.
    • Repeat this step for a total of 3 washes.
  11. Add the SYBR gold DNA stain to your CometChip and carefully move it to the 4 °C cooler.
    • Stain CometChip overnight.

Part 5: Edit homework assignment

Using the pointers from the Comm Lab workshop, edit the figure (not the bullet text!) you prepared for the homework assignment due today. You can submit the updated figure by 10 pm tonight for grading. You will get a grade for submitting the original figure on-time and the updated figure will be graded for content. If you choose not to update your homework, the figure already submitted will be graded for content.

Reagents list

  • agar, normal melting point (from Invitrogen)
  • GelBond film (from Lonza)
  • agar, low melting point (from Invitrogen)
  • phosphate buffered saline (PBS) (from VWR)
  • Dulbecco's phosphate buffered saline (DPBS) (from Sigma)
  • alkaline lysis solution: 2.5 M NaCl, 100 mM Na2EDTA, 10 mM Tris, 1% Trition-X
  • alkaline electrophoresis solution: 0.3 M NaOH, 1 mM Na2EDTA, pH 13.5 (from Sigma)
  • neutralization buffer: 0.4 M Tris, pH 7.5 (from Sigma)
  • SYBR gold DNA stain (from ThermoFisher)

Navigation links

Next day: Image and analyze high-throughput genome damage assay

Previous day: Image repair foci experiment and quantify results