− | The [https://en.wikipedia.org/wiki/Patch_clamp patch clamp] is a technique for measuring voltages produced by electrically active cells such as neurons. A circuit model for a neuron connected to a patch clamp apparatus consists of a time-varying voltage source in series with an output impedance of 10<sup>11</sup> Ω. There is an oscilloscope next to the neuron with an ''input impedance'' of 10<sup>6</sup> Ω and an input capacitance of 20 pFd. A new UROP in the lab attempts to measure the electrical spikes produced by a neuron (called ''action potentials'') by connecting the patch clamp apparatus to the oscilloscope with a cable that has a capacitance of 80 pFd. Action potentials are about 100 mV in amplitude and about 1 ms in duration. | + | The [https://en.wikipedia.org/wiki/Patch_clamp patch clamp] is a technique for measuring voltages produced by electrically active cells such as neurons. A circuit model for a neuron connected to a patch clamp apparatus consists of a time-varying voltage source in series with an output impedance of 10<sup>11</sup> Ω. There is an oscilloscope next to the neuron with an ''input impedance'' of 10<sup>6</sup> Ω and an input capacitance of 20 pFd. A new UROP in the lab attempts to measure the electrical spikes produced by a neuron (called ''action potentials'') by connecting the patch clamp apparatus to the oscilloscope with a cable that has a capacitance of 80 pFd. Action potentials are about 100 mV in amplitude and about 1 ms in duration. You can model the noise in the oscilloscope as a random, additive, normally distributed voltage with a standard deviation of 10<sup>-3</sup> V. |
[[File:Patch clamp circuit model.png|750px]] | [[File:Patch clamp circuit model.png|750px]] | ||
Revision as of 22:01, 25 October 2018
This is Part 2 of Assignment 6.
Ideal elements
Resistive circuits
For each of the circuits below, find the voltage at each node and the current through each element. |
1 | 2 |
---|---|
3 | |
Equivalent circuits
Measuring action potentials
The patch clamp is a technique for measuring voltages produced by electrically active cells such as neurons. A circuit model for a neuron connected to a patch clamp apparatus consists of a time-varying voltage source in series with an output impedance of 1011 Ω. There is an oscilloscope next to the neuron with an input impedance of 106 Ω and an input capacitance of 20 pFd. A new UROP in the lab attempts to measure the electrical spikes produced by a neuron (called action potentials) by connecting the patch clamp apparatus to the oscilloscope with a cable that has a capacitance of 80 pFd. Action potentials are about 100 mV in amplitude and about 1 ms in duration. You can model the noise in the oscilloscope as a random, additive, normally distributed voltage with a standard deviation of 10-3 V.
Easy Bode plots
1 | 2 |
---|---|
3 | 4 |
Harder Bode plots
1 | 2 |
---|---|
Linear systems
1 | 2 |
---|---|
Second-order system
Find the transfer function $ H(\omega)=\frac{V_{out}}{I_{in}} $ for the circuit below. |